Stay with the utility
Continue buying electricity without purchasing a system.
Understand what a system might produce, what electricity could still cost, and how solar affects the economics of owning an Arizona home.
Independent research. Be educated. Not sold.™
Explore your numbers →Four questions. Arizona weather modeling. No utility account, quote or spreadsheet required.
Typical-year production includes selected orientation and assumed losses with 20° roof tilt. PVWatts does not inspect a particular roof or calculate utility savings.
Production estimates are not rooftop inspections or verified dollar savings.
All detailed controls remain below: Arizona rate plans, hourly usage, export credits, demand charges and financial assumptions.
← Return to Quick EstimateYour annual utility bill and a real system quote are more useful than a generic savings promise.
Weekday reference schedules for supported plans. Exact bills depend on holidays, billing dates and your hour-by-hour electric load, not the schedule alone.
Winter additionally has super off-peak 10 a.m.–3 p.m.
Super off-peak 10 a.m.–3 p.m. weekdays.
Super off-peak 8 a.m.–3 p.m. daily; summer rates vary by billing month.
Three monthly kWh tiers: 500 and 1,000 kWh
Peak windows on weekdays only; holidays and weekends off-peak.
Two monthly kWh tiers: 400 kWh
Peak windows on weekdays only; holidays and weekends off-peak.
Dates and windows differ by utility. The calculator uses approximate seasonal consumption shares—not the home’s interval meter data.
Published cents per kWh unless stated otherwise. For TOU, each monthly billing period progresses through the listed consumption tiers. Demand TOU does not use tiered energy prices.
| Rate and season | On-peak kWh | Off-peak kWh | Demand charge |
|---|---|---|---|
| TEP TOU · summer 0–500 kWh | 19.27¢ | 12.19¢ | — |
| TEP TOU · summer 501–1,000 | 20.56¢ | 13.47¢ | — |
| TEP TOU · summer 1,001+ | 21.28¢ | 14.19¢ | — |
| TEP TOU · winter 0–500 | 13.33¢ | 12.48¢ | — |
| TEP TOU · winter 501–1,000 | 14.61¢ | 13.77¢ | — |
| TEP TOU · winter 1,001+ | 15.33¢ | 14.49¢ | — |
| UniSource TOU · summer 0–400 | 18.60¢ | 9.61¢ | — |
| UniSource TOU · summer 401+ | 19.86¢ | 10.87¢ | — |
| UniSource TOU · winter 0–400 | 16.05¢ | 9.10¢ | — |
| UniSource TOU · winter 401+ | 17.31¢ | 10.36¢ | — |
| TEP Demand TOU · summer / winter | 14.37¢ / 8.43¢ | 7.29¢ / 7.58¢ | $11.60/kW first 7; $16.85 thereafter |
| UniSource Demand TOU · summer / winter | 15.87¢ / 13.31¢ | 6.88¢ / 6.37¢ | $6.82/kW first 7; $9.61 thereafter |
All amounts exclude the utilities’ changing purchased-power adjustment, other riders, taxes and franchise assessments. Peak demand is the highest applicable one-hour average within a billing period; this prototype asks for an estimated kW value rather than actual metering.
These visual schedules are explanatory, not a substitute for meter-level modeling. Rate exceptions apply for weekends and observed holidays. APS R-3 also adds the highest applicable on-peak hourly demand.
Figures below are cents per kWh except demand charges. These are tariff components, not complete bills. SRP temporary 2026 fuel adjustments are excluded.
| Rate plan and season | Peak | Off-peak | Super off-peak | Demand charge |
|---|---|---|---|---|
| APS TOU-E — summer | 34.396¢ | 12.345¢ | — | — |
| APS TOU-E — winter | 32.543¢ | 12.351¢ | 3.495¢ | — |
| APS R-3 — summer | 14.227¢ | 5.943¢ | — | $19.585/kW |
| APS R-3 — winter | 9.932¢ | 5.938¢ | 3.495¢ | $13.747/kW |
| SRP Conserve — winter | 15.08¢ | 13.55¢ | 4.32¢ | — |
| SRP Conserve — May/Jun/Sep/Oct | 18.85¢ | 15.06¢ | 3.95¢ | — |
| SRP Conserve — July/Aug | 40.20¢ | 12.76¢ | 6.61¢ | — |
APS TOU-E has no demand charge. R-3 calculates demand from the highest applicable on-peak hourly kW. SRP Conserve has no demand charge. Solar exports and connection fees are separate from these prices.
Electricity savings and total cost after financing are two different numbers.
The chart and comparison cards show conditional scenarios, not verified savings. The 20-year conclusion and payback are withheld when bills, rate plans or the modeled baseline have not passed initial screening. Even a screened scenario is not an engineering or financial recommendation until production and hourly utility bills are validated.
Without solar
Before system financing
Utility savings only
Electricity plus financing or purchase
Illustrative cash scenario: modeled pre-solar annual utility cost is about 19% below the entered bill. Reconcile the actual rate plan and charges before using the estimate.
Designer sample: annual panel degradation 0.5%, owner upkeep $150, inverter replacement in year 13 at $2,500. Preview recalculates from your actual inputs.
Bills shown here use verified base tariff components for selected plans—not actual meter data. Export eligibility, adjustment riders, taxes, holidays, demand intervals and billing-cycle boundaries need further verification. Long-term rates are scenarios, not predictions.
A working comparison, not a forecast of APS/SRP prices.
Gray: No solar · Green: With solar
Headline 20-year savings withheld until bills and tariffs are reconciled.
Excludes future rate inflation, depreciation, equipment replacement, tax incentives, and maintenance.
Solar can reduce utility purchases without necessarily reducing total ownership cost.
The result should be unfavorable when solar does not pay for itself. That is a feature, not a defect.
Azimuth, roof tilt, shade, equipment losses and local weather change production. This early model uses an adjustable annual yield and orientation factor, not an address-specific solar simulation.
Accurate estimates require an exact rate plan, time-of-use schedules, export credit eligibility, and applicable fixed or demand charges. These integrations are not complete.
Solar loans add payments; cash purchases require capital up front. Batteries may need replacement. Neither should be hidden inside electric-bill savings.
This draft models selected published tariff components for APS, SRP, Tucson Electric Power and UniSource Electric, across seven residential solar rate scenarios. Hourly usage, taxes, demand intervals, export eligibility and changing price adjustments still require verification. See utility sources and limitations below.
Educational research prototype. Not engineering, tax, financial or utility-billing advice. Verify all utility rate, equipment, roof and loan terms.
$0.458/day basic service; $0.242/kW DC/month grid access. Seasonal TOU energy schedule.
View official tariff or plan ↗$0.458/day basic service; $0.215/kW DC/month grid access. Demand $19.585/kW summer and $13.747/kW winter.
View official tariff or plan ↗Monthly service tiers $20/$30/$40, published season/TOU energy rates; export 1.87¢/kWh effective May 2026.
View official tariff or plan ↗$12/month single-phase TOU service charge. Summer May–September peaks 3–7 p.m.; winter Oct–April peaks 6–9 a.m. and 6–9 p.m. Three monthly energy tiers. New 2026 RCP tranche 4.62¢/kWh.
TEP TOU pricing ↗TEP export compensation ↗$14/month residential TOU service charge. Summer May–October peaks 3–7 p.m.; winter Nov–April peaks 6–9 a.m. and 6–9 p.m. Two monthly energy tiers. Export rate must be checked against the interconnection application.
UniSource TOU pricing ↗UniSource export compensation ↗Published rate schedules are not guaranteed for the 20-year system lifetime. APS export credits can vary by interconnection eligibility and vintage. Taxes, adjustors, billing-cycle rules and meter-specific interval consumption still need separate verification. SRP temporary May–October 2026 power-cost reductions are not projected into future years.
A $150/month starting payment can look attractive. With a 2.9% annual escalator, the monthly obligation rises every contract year—even if electric prices rise more slowly. This is a hypothetical lease example, not a quote.
The contract specifies an initial monthly payment and annual escalator. The homeowner pays the lease company and still pays APS or SRP for purchased electricity.
Example formula: monthly payment in year n = starting payment × (1 + escalator) to the power of (n − 1).
The agreement charges for contracted solar production, which may change over time. The kWh price can escalate while panel output declines. The homeowner still pays the utility for net imports.
Illustrative formula: annual PPA cost = annual billed generation × contract rate per kWh × escalation multiplier.
Some financing provides an initial payment that increases after an expected large principal prepayment, sometimes around month 19. Do not assume a tax credit will be available to fund that prepayment.
Use the signed lender's initial and later payment amounts. The model does not verify remaining principal or payoff balances.
Consumer references: CFPB: Solar Financing and FTC: Solar Power for Your Home.
We separate checked calculations from estimates that still need customer data. A favorable financial result does not mean the model fits a particular home.
Checked base energy and fixed-charge arithmetic for seven modeled APS, SRP, TEP and UniSource residential plans, including TEP three-tier and UniSource two-tier TOU rates; fixed-loan mathematics; annual lease/PPA escalators; solar degradation; and 20-year arithmetic. These are synthetic test cases, not bill-matching validation.
Meter interval consumption, precise roof production, holidays, billing-cycle changes, taxes and adjustors, export eligibility, PPA metering terms, lease transfer or buyout, loan payoff balances and actual APS/SRP bills.
Pre-solar bill differences greater than 10% trigger a warning; matching within 10% does not prove the calculation is accurate. Published tariffs are a snapshot, not live household billing information.