Kyle HayesHayes Real Estate Lab™
THE LAB / HOME OWNERSHIP ECONOMICS

Does solar make financial sense for your home?

Understand what a system might produce, what electricity could still cost, and how solar affects the economics of owning an Arizona home.

Independent research. Be educated. Not sold.™

Explore your numbers →
SOLAR MADE SIMPLE

How much electricity could solar generate?

Four questions. Arizona weather modeling. No utility account, quote or spreadsheet required.

Nearby reference point, not your exact roof.

Not sure? 8 kW is a hypothetical starting point.

South is an assumption when unknown.

Illustrative system losses, not a shade survey.

Estimate solar output using your chosen assumptions.

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
PVWATTS V8 · TYPICAL WEATHER YEAR

Your estimated solar production

Annual electricity—kWh AC per year
Average month—kWh AC per month
Highest-output month—Modeled
Estimated solar production through the year
—
Jan
—
Feb
—
Mar
—
Apr
—
May
—
Jun
—
Jul
—
Aug
—
Sep
—
Oct
—
Nov
—
Dec

Typical-year production includes selected orientation and assumed losses with 20° roof tilt. PVWatts does not inspect a particular roof or calculate utility savings.

Want to model your electric bill?

Continue with utility plans, hourly use, export credits and financing in the advanced model.

Open Advanced Model →

Production estimates are not rooftop inspections or verified dollar savings.

ADVANCED MODEL

All detailed controls remain below: Arizona rate plans, hourly usage, export credits, demand charges and financial assumptions.

← Return to Quick Estimate
01 / RUN YOUR SCENARIO

Start with the numbers you know.

Your annual utility bill and a real system quote are more useful than a generic savings promise.

Published tariffs + modeled consumption: APS TOU-E, APS R-3 and SRP Conserve 6–9 p.m. are available. Their listed energy, fixed-service and applicable solar grid-access or demand charges are used. Your hourly usage, solar output, taxes, adjustment riders, interconnection-specific export terms and future rate changes still require verification, so results are illustrative—not a utility bill quote.
Educational prototype — not live APS or SRP pricing. The current version models illustrative electricity savings. It does not yet account for current time-of-use schedules, demand charges, actual export tariffs, or verified property-specific solar production.

Choose the company shown on your electric bill.

Affects regional guidance, not an automatic PVWatts weather estimate.

12-month average

From utility statements

Quoted capacity

Before incentives

Preliminary adjustment

Solar payments shown separately

Used for loan financing

BEFORE-SOLAR BASELINE

Compare against what the home actually pays.

The current utility plan may differ from a solar-compatible plan. Start with 12 months of actual electric statements rather than a simulated rate plan.

This records the existing plan but does not yet calculate its separate tariff.

Sum 12 months of statements and divide by 12.

Illustrative comparison only

The model will not show a validated payback until real bills are entered and the assumptions reconcile.

Do not upload customer account numbers, names or addresses. Use dollar totals only, including consistent taxes and fees; identify unusual credits.

Location context

Phoenix-area scenario. APS or SRP depends on the home's service address. Annual production is based on your editable kWh/kW yield, not yet on PVWatts weather data.

Snow and tree-shade percentages reduce modeled solar output. Leave them at 0% if already included in your annual production estimate to avoid double counting.

FLAGSTAFF / NORTHERN ARIZONA

Same APS electricity rates. Different rooftop conditions.

Flagstaff's snowy winters and pine-tree canopy can change the production profile of a particular roof. Cooler operating temperatures can help photovoltaic efficiency, but a geographic preset alone cannot determine annual energy output.

Snow and shade: Enter annual losses if known. A 0% snow entry assumes no annual production is lost to lingering coverage.

Winter electricity: If the home uses a heat pump or electric heating, adjust the May–October consumption share using utility statements.

Production validation: A roof-specific PVWatts result should replace the manual annual-yield placeholder. Avoid counting snow or tree shading twice.

Adjust technical assumptions +
ADVANCED INPUTS

Solar production assumptions

Refine expected generation, the share used by the home, and export compensation. These are not measurements of the property.

SOLAR PRODUCTION DATA

Choose measured data or PVWatts if available.

Enter total AC kWh from the PVWatts report or production monitoring.

Illustrative mode: roof direction, additional snow and shade losses are separately applied to the entered kWh-per-kW yield. This isn't a validated site-specific production estimate.

Open NREL PVWatts to estimate annual AC production ↗
PVWATTS V8 · SITE-SPECIFIC ESTIMATE

Generate a solar-production estimate

Enter approximate rooftop coordinates and roof geometry. No utility account or homeowner identity is needed. This is a weather-model estimate, not a production guarantee.

180° = south, 90° = east, 270° = west

If shading and snow are included here, do not add them again elsewhere.

Estimate solar generation →

Staging integration. Requires server connection and a securely configured NLR API key.

Estimated monthly solar generationAC kWh · typical weather year
—
Jan
—
Feb
—
Mar
—
Apr
—
May
—
Jun
—
Jul
—
Aug
—
Sep
—
Oct
—
Nov
—
Dec

Production is based on PVWatts weather and the equipment assumptions above. It does not calculate utility bill savings until your electricity-use profile is also provided.

HOURLY ENERGY BALANCE · STAGING

How much solar would your home use?

Compare hourly PVWatts generation with a full year of household electricity use. This preliminary model separates energy used directly, electricity bought from the grid and surplus sent back. It does not yet calculate your utility bill.

1 · Generate 8,760 hourly solar estimates

First enter coordinates and roof details above. This requests a full typical-weather-year series for the current solar system.

2 · Import your own hourly or 15-/30-minute usage
Read and check usage file

CSV columns: timestamp,kwh. Example: 2025-01-01 00:00,1.25. Supports 8,760 hourly, 17,520 half-hourly, or 35,040 quarter-hourly intervals. Use pre-solar gross household consumption, not net grid imports from a home that already has solar. Do not include account numbers or addresses.

No file read. Only complete non-leap-year profiles are accepted. Files are processed locally and are not sent to our server.

NO UTILITY STATEMENTS NEEDED

Try an illustrative household load

Explore a full year of synthetic electricity use without uploading any records. These profiles help demonstrate the calculations and are not reconstructed from actual customer bills or meteorological observations.

The annual kWh amount comes from the calculator's annual electricity-use field above.

Example data only. No bill verification, financial comparison or rate-plan calibration is implied.

Household use—kWh / year
Solar used at home—kWh / year
Surplus exported—kWh / year
Purchased from grid—kWh / year
Awaiting real consumption data. We will not estimate solar self-consumption from an arbitrary percentage.
Solar generatedHousehold usedGrid purchases
Jan—
Feb—
Mar—
Apr—
May—
Jun—
Jul—
Aug—
Sep—
Oct—
Nov—
Dec—

Monthly bars are grouped for comparison. They show energy, not utility rates, taxes, demand charges or guaranteed savings. PVWatts uses a typical meteorological year; real usage is mapped to its month/day/hour pattern for this preliminary test.

TARIFF RECONSTRUCTION · PRELIMINARY

What would the energy charges look like?

Use the selected APS, SRP, TEP or UniSource electric rate plan with the hourly solar and household-usage comparison above. This computes published base charges, time-of-use energy prices, peak demand where applicable and potential export compensation. It is not a reconstructed utility bill.

2025 is used to map the typical-year hourly profile to weekdays. Actual billing periods can cross months.

Banked credits, settlement and eligibility vary.

Load hourly solar and household usage above to generate the comparison.
Same-plan baseline · no solar—Modeled annual tariff components
With rooftop solar · before credits—Energy, fixed and demand charges
Potential export-credit value—Not guaranteed cash savings
Component difference, before credits—Not verified savings
MonthNo solarWith solarPotential creditSolar peak kW
Jan————
Feb————
Mar————
Apr————
May————
Jun————
Jul————
Aug————
Sep————
Oct————
Nov————
Dec————

Interpretation: Both sides use the same selected solar-compatible plan, not necessarily the current homeowner plan. Months are calendar months, not meter-read billing periods. Demand plans use highest on-peak one-hour imports. Holidays are approximated. Tiered TOU allocates monthly kWh proportionally across time periods. SRP bills can depend on meter-read season. Taxes, fuel/purchased-power adjustors, local fees, minimum charges, banked credits, grandfathered net metering and actual battery dispatch are excluded. Confirm tariff eligibility and export agreement.

Heuristic, not PVWatts

Direct consumption share

Example, not a verified tariff

APS/TEP/UniSource credits can depend on interconnection vintage; SRP rates may reset annually.

0% assumes no annual snow loss. Enter a site-specific estimate.

Only additional shade loss not included in the entered annual yield.

UTILITY RATE & LONG-TERM OWNERSHIP

Account for the costs that remain.

Published rate components where verified; usage timing, export vintage, additional adjustors and future prices remain uncertain.

Plan eligibility depends on your interconnection and utility account.

Depends on SRP electric service

Weekday peak-hour consumption

Where the plan has this period

Cooling-season share

Only APS R-3; highest peak hour

Only APS R-3; assumption

Annual output decay

Scenario, not a forecast

Maintenance budget

Zero disables replacement

Estimated installed replacement cost

Scenario only: TEP/UniSource RCP rate locks last up to 10 years; actual later rates are unknown.

Basic connection chargeAPS $0.458/day
Solar grid-access charge$0.242/kW DC/month
On-peak windowWeekdays 4–7 p.m.
Export compensationContract-specific for APS

APS tariff base components only. Additional bill adjustors, taxes, fees and contract-specific exports are not included.

FINANCING / OWNERSHIP CONTRACT

What kind of solar agreement comes with the home?

A fixed loan, an escalating lease, and a PPA produce different 20-year costs. Enter the actual contract terms.

Choose the arrangement from the actual contract

Year-one amount, before the annual escalator

Applied once per year; compounded

Paid per solar kWh produced, not just consumed

Price escalates while output may degrade

20–30 years; this chart shows the first 20

Before scheduled payment change

After scheduled payment change

For example, after 18 payments

Deposit or prepaid lease amount

May exceed the quoted cash purchase price; actual signed loan amount controls payments.

Cash purchase example

Designer sample: cash purchase with the system cost paid upfront. Preview calculations reflect the agreement type you select.

Year-one contract cost$0
Year-10 contract cost$0
20-year contract payments$0

For leases and PPAs, the system owner usually handles covered maintenance. Contract transfer, buyout, removal, escalator exceptions and rooftop work must be reviewed separately.

Inputs stay in your browser. No data submission.

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
UTILITY HOURS / PEAK MATTERS

When you use energy matters.

Weekday reference schedules for supported plans. Exact bills depend on holidays, billing dates and your hour-by-hour electric load, not the schedule alone.

APS summer4–7 p.m. weekdays

Winter additionally has super off-peak 10 a.m.–3 p.m.

APS winter4–7 p.m. weekdays

Super off-peak 10 a.m.–3 p.m. weekdays.

SRP Conserve solar6–9 p.m. weekdays

Super off-peak 8 a.m.–3 p.m. daily; summer rates vary by billing month.

Off-peakSuper off-peakPeak
SOUTHERN ARIZONA · TIME-OF-USE WINDOWS
TEP · Tucson

Three monthly kWh tiers: 500 and 1,000 kWh

May–September3–7 p.m.
October–April6–9 a.m. and 6–9 p.m.

Peak windows on weekdays only; holidays and weekends off-peak.

UniSource Electric

Two monthly kWh tiers: 400 kWh

May–October3–7 p.m.
November–April6–9 a.m. and 6–9 p.m.

Peak windows on weekdays only; holidays and weekends off-peak.

Dates and windows differ by utility. The calculator uses approximate seasonal consumption shares—not the home’s interval meter data.

TEP + UNISOURCE ELECTRIC / RESIDENTIAL BASE RATES

Southern Arizona tariff comparison

Published cents per kWh unless stated otherwise. For TOU, each monthly billing period progresses through the listed consumption tiers. Demand TOU does not use tiered energy prices.

Rate and seasonOn-peak kWhOff-peak kWhDemand charge
TEP TOU · summer 0–500 kWh19.27¢12.19¢—
TEP TOU · summer 501–1,00020.56¢13.47¢—
TEP TOU · summer 1,001+21.28¢14.19¢—
TEP TOU · winter 0–50013.33¢12.48¢—
TEP TOU · winter 501–1,00014.61¢13.77¢—
TEP TOU · winter 1,001+15.33¢14.49¢—
UniSource TOU · summer 0–40018.60¢9.61¢—
UniSource TOU · summer 401+19.86¢10.87¢—
UniSource TOU · winter 0–40016.05¢9.10¢—
UniSource TOU · winter 401+17.31¢10.36¢—
TEP Demand TOU · summer / winter14.37¢ / 8.43¢7.29¢ / 7.58¢$11.60/kW first 7; $16.85 thereafter
UniSource Demand TOU · summer / winter15.87¢ / 13.31¢6.88¢ / 6.37¢$6.82/kW first 7; $9.61 thereafter

All amounts exclude the utilities’ changing purchased-power adjustment, other riders, taxes and franchise assessments. Peak demand is the highest applicable one-hour average within a billing period; this prototype asks for an estimated kW value rather than actual metering.

These visual schedules are explanatory, not a substitute for meter-level modeling. Rate exceptions apply for weekends and observed holidays. APS R-3 also adds the highest applicable on-peak hourly demand.

PUBLISHED BASE ENERGY RATE REFERENCE

What the utilities list

Figures below are cents per kWh except demand charges. These are tariff components, not complete bills. SRP temporary 2026 fuel adjustments are excluded.

Rate plan and seasonPeakOff-peakSuper off-peakDemand charge
APS TOU-E — summer34.396¢12.345¢——
APS TOU-E — winter32.543¢12.351¢3.495¢—
APS R-3 — summer14.227¢5.943¢—$19.585/kW
APS R-3 — winter9.932¢5.938¢3.495¢$13.747/kW
SRP Conserve — winter15.08¢13.55¢4.32¢—
SRP Conserve — May/Jun/Sep/Oct18.85¢15.06¢3.95¢—
SRP Conserve — July/Aug40.20¢12.76¢6.61¢—

APS TOU-E has no demand charge. R-3 calculates demand from the highest applicable on-peak hourly kW. SRP Conserve has no demand charge. Solar exports and connection fees are separate from these prices.

02 / SEE THE FULL COST

Your illustrative results.

Electricity savings and total cost after financing are two different numbers.

How to read these numbers

The chart and comparison cards show conditional scenarios, not verified savings. The 20-year conclusion and payback are withheld when bills, rate plans or the modeled baseline have not passed initial screening. Even a screened scenario is not an engineering or financial recommendation until production and hourly utility bills are validated.

Electric cost now / year
$2,327

Without solar

Utility bill with solar / year
$1,209

Before system financing

Electricity savings / year
Illustrative

Utility savings only

Year-one total cash outlay
$25,359

Electricity plus financing or purchase

How closely does the model match your real bill?

Illustrative cash scenario: modeled pre-solar annual utility cost is about 19% below the entered bill. Reconcile the actual rate plan and charges before using the estimate.

Designer sample: annual panel degradation 0.5%, owner upkeep $150, inverter replacement in year 13 at $2,500. Preview recalculates from your actual inputs.

Bills shown here use verified base tariff components for selected plans—not actual meter data. Export eligibility, adjustment riders, taxes, holidays, demand intervals and billing-cycle boundaries need further verification. Long-term rates are scenarios, not predictions.

Cumulative 20-year costs

A working comparison, not a forecast of APS/SRP prices.

Gray: No solar   ·   Green: With solar

20-YEAR DIFFERENCE
Not validated

Headline 20-year savings withheld until bills and tariffs are reconciled.

Simple cash paybackNot validated
Annual solar production12,800 kWh
Monthly loan paymentCash purchase

Excludes future rate inflation, depreciation, equipment replacement, tax incentives, and maintenance.

03 / COMPARE THE TRADEOFFS

Three ways forward.

Solar can reduce utility purchases without necessarily reducing total ownership cost.

01 / NO SOLAR

Stay with the utility

Continue buying electricity without purchasing a system.

Annual electricity$2,327
20-year total$46,531
02 / SOLAR ONLY

Own the panels

Purchase or finance a solar array and pay the remaining utility cost.

Annual utility bill$1,209
20-year all-in cost$54,726
03 / SOLAR + BATTERY

Add energy storage

Modeled greater on-site solar usage with a $12,000 battery add-on.

Annual utility billIllustrative
20-year all-in costSee preview

Battery replacement costs are not included.

04 / OPEN METHODOLOGY

The assumptions are part of the answer.

The result should be unfavorable when solar does not pay for itself. That is a feature, not a defect.

Solar production

Azimuth, roof tilt, shade, equipment losses and local weather change production. This early model uses an adjustable annual yield and orientation factor, not an address-specific solar simulation.

APS, SRP, TEP and UniSource tariffs

Accurate estimates require an exact rate plan, time-of-use schedules, export credit eligibility, and applicable fixed or demand charges. These integrations are not complete.

Ownership economics

Solar loans add payments; cash purchases require capital up front. Batteries may need replacement. Neither should be hidden inside electric-bill savings.

RESEARCH & VERIFICATION

Follow the source.

This draft models selected published tariff components for APS, SRP, Tucson Electric Power and UniSource Electric, across seven residential solar rate scenarios. Hourly usage, taxes, demand intervals, export eligibility and changing price adjustments still require verification. See utility sources and limitations below.

Educational research prototype. Not engineering, tax, financial or utility-billing advice. Verify all utility rate, equipment, roof and loan terms.

PRIMARY TARIFF SOURCES · APS/SRP REVIEWED OCT 22, TEP/UNISOURCE OCT 23, 2026
APS TOU-E

$0.458/day basic service; $0.242/kW DC/month grid access. Seasonal TOU energy schedule.

View official tariff or plan ↗
APS R-3 demand

$0.458/day basic service; $0.215/kW DC/month grid access. Demand $19.585/kW summer and $13.747/kW winter.

View official tariff or plan ↗
SRP Conserve Solar

Monthly service tiers $20/$30/$40, published season/TOU energy rates; export 1.87¢/kWh effective May 2026.

View official tariff or plan ↗
Tucson Electric Power

$12/month single-phase TOU service charge. Summer May–September peaks 3–7 p.m.; winter Oct–April peaks 6–9 a.m. and 6–9 p.m. Three monthly energy tiers. New 2026 RCP tranche 4.62¢/kWh.

TEP TOU pricing ↗TEP export compensation ↗
UniSource Electric

$14/month residential TOU service charge. Summer May–October peaks 3–7 p.m.; winter Nov–April peaks 6–9 a.m. and 6–9 p.m. Two monthly energy tiers. Export rate must be checked against the interconnection application.

UniSource TOU pricing ↗UniSource export compensation ↗

Published rate schedules are not guaranteed for the 20-year system lifetime. APS export credits can vary by interconnection eligibility and vintage. Taxes, adjustors, billing-cycle rules and meter-specific interval consumption still need separate verification. SRP temporary May–October 2026 power-cost reductions are not projected into future years.

FINANCIAL ENGINEERING / SOLAR AGREEMENTS

An escalator changes the economics.

A $150/month starting payment can look attractive. With a 2.9% annual escalator, the monthly obligation rises every contract year—even if electric prices rise more slowly. This is a hypothetical lease example, not a quote.

YEAR 1$150##INLINE1##
YEAR 5$168##INLINE3##
YEAR 10$194##INLINE5##
YEAR 15$224##INLINE7##
YEAR 20$258##INLINE9##

Lease: escalating monthly payments

The contract specifies an initial monthly payment and annual escalator. The homeowner pays the lease company and still pays APS or SRP for purchased electricity.

Example formula: monthly payment in year n = starting payment × (1 + escalator) to the power of (n − 1).

PPA: escalating price per kWh

The agreement charges for contracted solar production, which may change over time. The kWh price can escalate while panel output declines. The homeowner still pays the utility for net imports.

Illustrative formula: annual PPA cost = annual billed generation × contract rate per kWh × escalation multiplier.

Loan: payment reset or re-amortization

Some financing provides an initial payment that increases after an expected large principal prepayment, sometimes around month 19. Do not assume a tax credit will be available to fund that prepayment.

Use the signed lender's initial and later payment amounts. The model does not verify remaining principal or payoff balances.

Especially important when buying or selling a home: Request the complete lease, PPA or loan documents; remaining payments; price-escalator provision; transfer approval criteria; current payoff/buyout figure; equipment ownership; performance guarantees; and roof/removal obligations.

Consumer references: CFPB: Solar Financing and FTC: Solar Power for Your Home.

VALIDATION / CALCULATOR LIMITATIONS

What can this estimate support?

We separate checked calculations from estimates that still need customer data. A favorable financial result does not mean the model fits a particular home.

Checked in this draft

Checked base energy and fixed-charge arithmetic for seven modeled APS, SRP, TEP and UniSource residential plans, including TEP three-tier and UniSource two-tier TOU rates; fixed-loan mathematics; annual lease/PPA escalators; solar degradation; and 20-year arithmetic. These are synthetic test cases, not bill-matching validation.

Not validated against real bills

Meter interval consumption, precise roof production, holidays, billing-cycle changes, taxes and adjustors, export eligibility, PPA metering terms, lease transfer or buyout, loan payoff balances and actual APS/SRP bills.

Data needed for a reliable home-specific result: 12 months of utility bills, exact rate plan, interval electricity data if available, solar quote or production records, installation details and the signed cash/loan/lease/PPA agreement.

Pre-solar bill differences greater than 10% trigger a warning; matching within 10% does not prove the calculation is accurate. Published tariffs are a snapshot, not live household billing information.